Push button-based site programming of PT Ratio
Network selection for Star (3 Phases 4 wire) and Delta (3phase 3 wire)
Bright 4 Digit 14mm LED display
Colour indication for R, Y & B phases
Push button-based site programming of CT Ratio
Universal Auxiliary Supply : 80 to 300V AC/DC mfkaejnfkjfc nakfn
Push button-based site programming of CT & PT ratio.
Available in accuracy class 1.0 & 0.5 (Maintained Throughout the measurement range.)
Measurement range 0-3.000kW
Universal Auxiliary Supply : 80 to 300V AC/DC
Measurement range 40.00 - 99.99 Hz.
Accuracy Class 0.2 (Maintained throughout the measurement range.)
Bright 4 Digit 14mm LED display.
Universal Auxiliary Supply - 80 to 300V AC/DC.
Measurement range Zero Log Unity-Zero Lead
Accuracy - 0.01%
Lag / Lead indication on the display
Common Meter for kW, kVA and kVAr
User selectable measurement of kW/ kVAr/ kVA
Available in Class 0.5 & 1.0
Sustained accuracy throughout the range
CT Operated, -/5A in class 1.0 accuracy
Available up to 800/5A (for direct reading) (Ref. Catalogue for available CT Ratio)
No separate Auxiliary supply required
Low Power Consumption less than 1 watt per phase
CT Primary programmable up to 6000A
Low Power Cons. less than 1 watt per phase klmxsuzcbzsjhc
Backlit LCD display. ebrit : Kilo Watt Meter
CT operated -/5A in class 1.0 accuracy.
RS 485 communication
CT Primary programmable up to 6000A (For direct reading).
CT Primary : From 5A to 6000A in Multiples of 5 For CT secondary 5A From 1A to 1200 in Multiples of 1 for CT ...
CT Primary : From 5A to 6000A in Multiples of 5 For CT secondary 5A From 1A to
-/5A in class accuracy 1.0
Suitable for 3 Phase 4 Wire LT Network
Three-Line Backlit LCD Display
Optically Isolated Energy Pulse Output
RS485 MODBUS Communication
Provision for Special Screens Shots
-/5A in accuracy class 1.0
CT Primary Programmable up to 6000A
Three-Line Backlit LCD display.
Displays : Voltage, Current, Power, Energy
RS485 MODBUS RTU Communication (Optional)
Password Protected Programming
Backlit LCD type Display (16 X 2 line Dot Matrix)
-/5A in class 0.5 & 1.0 accuracy
Suitable for 3 Phase 4 Wire LT Network.
CT Primary Programing up to 6000A
Three-line LCD backlit display
Programmable CT secondary for 5A & 1A
Suitable for HT 3Phase 3 Wire /3 phase 4 wire (different model) application
Rs485 Communication (Optional)
CT Primary: From 5A to 9999A Configurable in multiples of 5 for -/5A & From 1A to 2000A configurable in multiple of 1 for -/1A CT Secondary : 5A/1A ...
Three-line LCD backlit display.
CDisplays: Voltage, Current, Power Factor, Power, Trivector Energy & THD.
Relay Output for V, I, Total kW, Total kVA, F, kW MD & kVA MD.
One meter records Active Energy of Two Sources
Relay outputs for V, I, kW, kVA, F, kW Demand, kVA demand
Last 6 months history parameters for kWh and MD through communication
Last 10 event logging for Mains / Generator switching
Current rating single phase 5-30A, three-phase 10-60A & 20-80A & /-5A
Communication: Modbus RTU for three-phase & pulse output for single phase
Programmable CT ratio and Scroll lock
Suitable of the dual-source application (only three-phase)
Current rating single phase 5-30A, three phase 10-60A & 20-80A & /-5A
Communication : Modbus RTU for three phase & pulse output for single phase
Suitable of dual source application (only three phase)
Microprocessor-based intelligent auto switching control.
Automatic C/K and rated step adjustment.
Automatic CT polarity correction.
Display of power factor, current & total harmonic distortion of current.